Bandwidth
|
DC to 50MHz (-3dB)
|
Attenuation Ratio
|
1/100
|
Accuracy
|
+/- 1%
|
Rise Time
|
<7ns
|
Input Impedance
|
4Mohm//7pF each side to ground
|
Input Voltage*
|
-Category
|
CAT II
|
-Differential Range
|
+/- 700V(DC+AC Peak ) and 600Vrms
|
-Common Mode Range
|
+/-1400V(DC+ AC Peak) and 600Vrms
|
-Absolute Max. Voltage
(either input to ground)
|
+/-1400V(DC+ AC Peak) and 600Vrms
|
Output
|
- Swing (into 5kohm load)
|
+/-7V
|
-Offset (typical)
|
<+/-1mV
|
-Noise (typical)
|
0.3mVrms
|
-Source Impedance (typical)
|
50 ohm
|
CMRR (typical)
|
-90dB @60Hz, -55dB @1MHz
|
Power Requirements**(Three options of power sources)
|
Mains adaptor(6VDC/90mA or 9VDC/70mA) Removable battery pack(4xAAcells) Power leads
|
Optional Extension Plugs for Mains Adaptor
|
-Input
|
One jack of 1A current rating.
|
-Output
|
Three plugs of 1A current rating
|
Ambient Operating Temperature
|
-10 to 40 degree centigrade
|
Ambient Storage Temperature
|
-30 to 70 degree centingrade
|
Ambient Operating Humidity
|
Up to 85% RH
|
Ambient Storage Humidity
|
Up to 85% RH
|
Length of BNC Cable
|
125cm
|
length of Input Leads
|
50cm
|
Weight
|
300gms
|
Dimension(LxWxH)
|
111mm x 22mm x 14mm
|